Chromatography
Related Topics
PU-2085 Micro
Fast becoming the standard for LC-MS applications requiring low flow-rates couple with high flow reliability, the PU-2000 series of pumps can be controlled by Analyst, Masslynx and XCalibur. The pump provides extremely consistent solvent delivery via SSQD (Slow Suction Quick Delivery).
The pump may be operated in normal operation mode or program mode. Normal operation mode offers a constant flow rate or pressure. In program mode, selection of composition, flow rate, solvent selection valves, and event relays can be performed according to a user-defined time program. For gradient pumping, both high-pressure (mixing) and low-pressure (mixing) methods are available. The appropriate method depends on the system being used.

Ideal for 1-2 mm columns and low flow rate gradients for LC/MS flow range 1 µl/min to 4 ml/min.
Specifications
| Type of pump: | SSQD method (Slow Suction, Quick Delivery) |
|---|---|
| Delivery mode: | Constant flow/constant pressure, selectable constant flow mode |
| Flow rate range: | 1 µl/min to 4.0 ml/min |
| Flow rate setting: | 1 µl/min to 4.0 ml/min with 1 µl steps by ten key operations |
| Flow rate precision: | Less than 0.1% (Relative Standard Deviation) from 0.05 - 1.0 ml/min |
| Flow rate accuracy: |
+/-2% of setting or +/-2 µl/min whichever is greater at 0.05 - 2.0 ml/min, 0 - 35 MPa |
| Max. pressure: | 35 MPa constant pressure mode |
| Pressure range: | 3 - 35 MPa |
| Pressure setting: |
Adjustable in 0.1 MPa increments by ten key operations |
| Pressure limit: |
Settable max, and min pressure limit in 0.1 MPa increments |
| Maximum pressure: | 0 - 50 MPa |
| Minimum pressure: | 0 - 50 MPa |
| Pressure sensor: | Flow through type strain-gauge transducer |
Other Features
| Display: | Flow rate, pressure, etc. are indicated on LCD |
|---|---|
| Time programming: | 64 steps, up to 10 files (maximum 999.9 min in 0.1 min increment) |
| Events output: | 3 provided, time programmable |
| Automatic pump on/off timer: | Provided, 0 - 99.9 hours (0.1 hours step) |
| Self-diagnostics: | Internal memory check, pressure sensor check, DC power supply check |
| Materials: | All materials in contact with solvent are ruby, sapphire, ceramic, stainless steel or fluorocarbon polymer |
| Plunger cleaning: | Provided as standard, automatic |
| Dimensions: | 150 (W) x 470 (D) x 150 (H) mm |
| Weight: Approx: | 10 kg |
| Power input voltage: | CC100 - 240 V +/-10% 50/60 Hz |
| Power consumption: | 185 VA |